CONFIDENTIALITY NOTICE: This webpage contains information which is (a) LEGALLY PRIVILEGED, PROPRIETARY IN NATURE, OR OTHERWISE PROTECTED BY LAW FROM DISCLOSURE, and (b) intended only for the use of the authorized persons. If you are not expressly authorized, you are hereby notified that reading, copying, or distributing this message is prohibited. If you have received a link to this page via electronic mail message in error, please contact us immediately at the telephone number shown above and take the steps necessary to delete the message completely from your computer system. Thank you.
# |
Who |
Cost |
Status |
Sys Name |
Location |
Description |
Resolution |
| *QRS resolved sys name and/or cable naming discrepancy. ITI implementing, not requiring cable relocation between racks. | |||||||
| **QRS/ITI Indicates RS will make drawing/database updates and ITI will install associated cables. | |||||||
| #1 | QRS | OPTIONAL | TRCG | RACK03 | Addition time code generator/reader to TC jackfield | Indicated as optional in subsequent report | |
| #2 | QRS | CG02 | RACK02 | The missing Typedeko computer was located in a box of equipment returned from ITI. Jeff will swap it into the 4RU PC and erase the password. Tomorrow we should be able to get CG/ key out of it. | |||
| #3 | QRS | DBETA01 | RACK01 | DBETA01 error 92 caused by defective ribbon cable running from subpanel to motherboard. Must be soldered at 40 points, no quick fix available. | |||
| #4 | QRS | N/A | N/A | No cabling problem- On drawing # DNC-SY0105 add feather indicating SY9008 from PSW2 ref to TBC01 reference in | |||
| #5 | QRS | N/A | N/A | No cabling problem-Cable label recreate error SY9909 to SY9911 and SY9315 to SY9022 as indicated on drawing # DNC-SY0105 | |||
| #6 | QRS | N/A | N/A | Correct jackfield label so that 9 CAV cables on bottom row of CJF01 (CV0128-CV0136) are in appropriate "normalling" position as indicated on drawing DNC-V1003 | |||
| #7 | QRS | N/A | N/A | No cabling problem-Cable label recreate error AV0148-150 should be AV0151-153 as indicated on drawing # DNC-V | |||
| #8 | QRS | N/A | N/A | No cabling problem- On drawing # DNC-V0902 change VADC and VDACs as follows: 03 to 05, 06 to 03, 07 to 04, 08 to 06, 09 to 07, 08 to 09, and 09 to 10 | |||
| #9 | QRS | DVJF-03 | RACK07 | Missing cabling problem-Cable recreate required for DV0312 and DV0313 as indicated on drawing # DNC-V0710, remove phantoms, relate to #15 | |||
| #10 | QRS | WFM01 | RACK10 | Tektronix 1750 WFM01 in rack10 has a very low trace level on | |||
| #11 | QRS | ABETA11 | RACK12L | ABETA11 audio misaligned. Not unity in E/E, but signal path proofs in bypass test | |||
| #12 | QRS | INTC | N/A | INTC11-21 (two modified RMS300 in wrong locations) and Sys Name for INTC13 should be INTC21 Corrected by Rick. Requires no ITI cabling changes | |||
| #13 | QRS | PSW21 | RACK02 | Sony VFS700 firmwave mismatch between CP and electronics. | |||
| #14 | QRS | VADC01 | VARIOUS | SVideo to SDI KW A/D converters are not functioning on any of the DVHS decks. Set to composite not YV | |||
| #15 | QRS | ACS01-ACS | RACK42 | Audio tie lines from ACS01-04 are not terminated at the AJF, which made it impossible to broadcast the audio from the ribbon cutting event through out the building or to tape it down in the TOC. It was my oversight not to verify this on Wednesday, but we found a work around by recording at the camera. | |||
| #16 | QRS | VADCxx | VARIOUS | KEYWEST CONVERSION -QRS wwill start calibrating the dozens of Keywest BVV2SD10 and BVVC2SD10 component A-D converters today using component and Y/C color bars. | |||
| #17 | QRS | VDACxx | VARIOUS | QRS will also be QCing each to ensure that there are no artifacts QRS whave seen in the past, such as translucent lines on the left side of the screen when viewed in underscan, and setup that is at 9.5 to 10 IRE when peak white is calibrated to 100 IRE. | |||
| #18 | QRS | WFVS01 | RACK10 | QRS whave brought in my Magni wWV561 component scope for use in this position until Media Systems/Tektronix returns one of the repaired 1750s. We need this loaner for QCing composite video in rack 9 while these DNC scopes are out of service. | |||
| #19 | QRS | WFVS01 | RACK10 | Juan Adrianza took both of the analog WFM/VS Tek 1750s for repair and alignment, but we can barrel the cables in the meantime. QRS whave a MagnQRS wcombo which QRS wcan bring in for the remainder of the testing as the 1750s may be out for some weeks at a minimum. | |||
| #20 | QRS | DSG01 | RACK03 | ADDITION: Add a DVDA to supply sdQRS wcolor bars to PSW1 so that we don't have to tie up a router destination to bring up bars. QRS wam not sure what QRS wshould do on PSW2 since it has only four SDI winputs. QRS wcan try to get another SDI winput module or QRS wcan D-A bars and feed it to one of the component analog inputs. The latter approach will be cheaper. | |||
| #21 | QRS | TM1-4 | RACK05 | TM03 (RACK05) is dead and must be replaced under warranty by Panasonic. ADDITION: had originally documented patchable NTSC inputs on these monitors at AVJF-03-21 through 3-24, but they are missing from the run list. I will restore these, and run them myself. | |||
| #22 | QRS | FS11-21 | VARIOUS | SDI FRAME SYNCS: For ease of user operations, (and knowing that they won't have a staff engineer), we will need to leave at least some Keywest frame syncs dedicated to the switcher inputs, OR install them in the PROC1 and PROC2 locations (as a low cost alternative to a real FS). This would not give users a way to adjust signal levels on these sources, but in the case of the camera, unity is desireable in any event. | |||
| #23 | QRS | FS11-21 | VARIOUS | There is still the intermittent jitter issue with these units and that must be addressed at the earliest opportunity. | |||
| #24 | QRS | DATA (KVM) | VARIOUS | We are missing the remote receive half of the Raritan KVM extender pair. Wesuspect that the one that we do have is defective (these are notoriously tempermental with a 25% infant mortality by my own experience.) We must locate that missing unit and also get a replacement for the defective one. Jeff ran and terminated two cables for this purpose and it appears that the problem is not in the KVM switch and not in Jeff's cables. We are missing other necessary cables to complete the installation. | |||
| #25 | QRS | MFS01-31 | VARIOUS | FINAL CUT/ MAC SYSTEMS: The Medea drives are not showing up on the desk tops when the Atto card is connected to the drives with the *correct* scsi cables that came by Fed Ex today. Wepredicted weeks ago that the real issue would be software compatibility between the various versions of the Aja Io software and drivers, Final Cut Pro IV, firmware in the Medea hardware raid, Apple OS X- 10.3XXX panther, etc etc. The order of installing these is critical. We can save time if there is a way to clone the first one Weget working. We will then only have to reinstall the FCP4 serial number. Jeff how can we clone an apple HD similar to Ghosting a windows HD? | |||
| #26 | QRS | PESA ROU | VARIOUS | The Pesa routing switcher has some issues with programming. We're getting error reports running the diagnostic and configuration editor programs. Wehave read enough of the PDF manual to know that we don't know enough of the programming to isolate and debug the errors. | |||
| #27 | QRS | PESA ROU | VARIOUS | We have disabled the TC level since we didn't get the Ocelot for the TC routing, and downloaded the new settings to the XYCPs. | |||
| #28 | QRS | PESA ROU | VARIOUS | We have left up the matrix switching program which eliminates the need to switch using just the crosspoint number, one level at a time. | |||
| #29 | QRS | PESA ROU | VARIOUS | The program I have left up on PC3 allows easy multilevel routing by a spreadsheet like interface. | |||
| #30 | QRS | PESA ROU | VARIOUS | The RCP-XP panels work, but not the sixteen buttons on the left. There is a programming discrepancy. Right now each button represents only the first sixteen crosspoints rather than each of the sixteen source groups, which once selected should allow the user to select two more digits for the device system name number. This was an oversite or error on the part of Pesa programmers, and they should follow up by correcting it. Also the RCP-XY legends, while correct, do not have numerals to indicate which button corresponds to which digit (should be 1 -8 on top row followed by 9 and 0 on the bottom row… | |||
| #31 | QRS | PESA ROU | VARIOUS | Clearly this points to the programmer misunderstanding how the control system should operate on a 16 button XY panel with a seven level router with up to 64 inputs and outputs. | |||
| #32 | QRS | PESA ROU | VARIOUS | The RS422 level is not communicating with the controller, and I suspect this has to do with the necessary PRC-232 interface cable on port 2. | |||
| #33 | QRS | DVHS01 | RACK02 | DVHS01 in rack 2 has failed on the SVHS playback side. I swapped it with DVHS2 from rack 10. Tom is going to take this up under warranty with Panasonic. | |||
| #34 | QRS/ITI** | DV0313 is same cable as item #69, DV0314 will be verified as connected | To be installed | N/A | N/A | Missing DV0313 and DV0314 from VADC09 and VADC10 (SatRx and FOR1) as show on drawing # DNC-V0709 | |
| #35 | QRS/ITI** | Cable labels were corrected | To be installed | AAJFxx | RACK08 | Label correction required on AA1919-AA1922 | |
| #36 | QRS/ITI** | CM21 | RACK21 | CM21 is not appearing as a router destination. System design calls for the component input of the BVM1910 is fed by VDAM21 (rtr output#63 which is fed by DVDA29. There is a signal discontinuity, so that RTR63 shows up at neither output of DVDA29 feeding VDAM21 and input C of VTM21. | |||
| #37 | QRS/ITI** | CM21 | RACK21 | CM21 is now seeing the A composite signal after resetting the BVM1910 firmware to factory defaults. QRS will have to do a similar restore to defaults in Edit C, but QRS need a Sony key for the locking electronics control drawer. | Rick obtained a key from Sony, will open monitor drawer today | ||
| #38 | QRS | JP-RJ45 | RACK2 | There are two cables labeled DT106 at RJ45 | |||
| #39 | ITI | AMA05/06 | RACK5 | AMA05 and AMA06 is in the correct location in Rack05 but should be mounted to the front rail rather than the rear rail. Please reverse when the following stereo pair are properly terminated. | |||
| #40 | ITI | AMA05 | RACK5 | Rick will install a pre-fab RCA male to mini stereo male for AA0167 AMA05 IHFA PC06 miniS-L and AA0168 AMA05 IHFB PC06 mini stereo jack which are missing but in the run list. | |||
| #41 | QRS | Prefab RCA stereo to 3.5mm Mini plug | AMA05 | RACK5 | AA0721 AMA05 BalAA to AAJF07 A21 and AA0722 AMA05 BalBB to AAJF07 A22 have been run but need screw terminal lugs in place of the RCA phono plugs. There are several feet of cable that is coiled up at the RCA male terminations which needs to be cut and dressed back to the appropriate length. | ||
| #42 | ITI | AMA05 | RACK5 | ITI will run and terminate a pair of cables for AA1858 RECV01 AUDL to AMA05 IHFAA and AA1859 RECV01 AUDR to AMA05 IHFBB which are in the run list, but missing. | |||
| #43 | ITI | AMA06 | RACK5 | AA0801 AMA06 BalAA to AAJF08 A01 and AA0802 AMA06 BalBB to AAJF08 A02 have been run but need screw terminal lugs in place of the RCA phono plugs. There are several feet of cable that is coiled up at the RCA male terminations which needs to be cut and dressed back to the appropriate length. | |||
| #44 | ITI | AMA06 | RACK5 | ITI will run and terminate a pair of cables for AA1867 PC06 miniS-L to AMA06 IHFAA and AA1868 PC06 miniS-R to AMA06 IHFBB which are in the run list, but not installed. | |||
| #45 | ITI | AMA06 | RACK5 | ITI will run and terminate a pair of cables for AA1845 AAJF18 B45 to AMA06 BalA and AA1846 AAJF18 B46 to AMA06 BalB which are in the run list, but not installed. | |||
| #46 | ITI | RJ-11-2 | RACK02 | Missing Tel21 and Tel51 was was indicated on the tape indicating what the brother p touch labels should be. I'd do it myself but ITI took the labeler with them. | |||
| #47 | QRS | VARIOUS | VARIOUS | Remotes to go where they need to go, affixed with velcro to the nearest shelf adjacent to or in proximity of each JVC mini DV-SVHS and the Panasonic DVD-4 decks. | |||
| #48 | ITI/QRS | VARIOUS | VARIOUS | Rick's VDAM testing/dip switch settings notes. Keywest V2S incorrectly installed VDAM 31 position. (needs velco) Replaced defective LSV.serial LSV00450 (does not output R/R-Y) , LSV00479 (output vertical lock instability), LSV00480 (output vertical lock instability), and LSV00481 (output vertical lock instability) with a working units. | |||
| #49 | QRS | N/A | NA | Rick needs working drawings to update AS BUILTS and so to subsequently generate FINAL JACKFIELD LABELS. | |||
| #50 | ITI/QRS | VARIOUS | VARIOUS | Rick/Kiitchi installed AVRS and PSW switcher keycap legends on seven switchers. Would like to have replacement lenses installed on the recycled Videotek RS-10A switchers to cover the laser labels Rick installed. This may require further trimming of the labels with an X-acto knife. | |||
| #51 | QRS | N/A | NA | Continue to clean up and organize studio and production area equipment. Transfer or other wise dispose of unneeded surplus. | |||
| #52 | ITI | N/A | Racks 1-11 | Lights have been installed at the tops of the racks rather than on the sides as a specified. Tie wrapping the light horizontally across the top rear of the rack serves no function. The lights have been left powered on. I would have chosen to plug them into the "switched" strips, or at very least, switched them off when not in use. More care should be made in dressing the power cables, not wrapped around signal cables as they are. The equipment in the racks blocks light reaching the equipment in the bottom. Tomorrow I will send a jpeg illustrating how the lights should be positioned. | |||
| #53 | ITI | VARIOUS | Rack 6 | Rack 6 conversion equipment is not connected as per system documentation. On his last site visit, Jim Babcock told me that he would ask Steve Hocker to come out to finish the work. | |||
| #54 | ITI | N/A | Racks 2, 3, | Many cables do not have only temporary labels, and several of these labels are not handwritten with only cable number information on masking tape. (Racks 2, 3, 4, 6 and 8) | |||
| #55 | ITI/QRS | VARIOUS | Rack 3 | Swap out spare Keywest BV and LV conversion equipment for replacement Keywest BVTBC10 frame syncs as discussed at NAB. | |||
| #56 | QRS | VARIOUS | Rack 3 | Install replacement Keywest BVTBC10 frame syncs and Y/C male to male and rack mounts which will be provided by Keywest via ITI as discussed at NAB. | |||
| #57 | QRS | TEL1 | Console | Locate and install missing power supply for the TS612 telephone hybrid control surface part number : 48800055. $91.50 first verify that PS or equivalent cannot be located at DNC. | |||
| #58 | ITI | PROC03 | Rack 9 | Install VPA-90 with rack mount located in Studio B. During clean up the rack mount was located but not VPA-90. Both were provided by ITI. Ishoud have been installed in the PROC 3 position (rack 09 - elev 36) as indicated in the system documentation? | |||
| #59 | ITI | VARIOUS | Rack 2 & 4 | Power supply jack panel was not labeled by Edit. RJ-11 jackpanel was labeled incompletely. The RJ-45 jack panel labels are peeling off. | |||
| #60 | QRS | DVC21 | Rack 21 | DVC-03 should be relocated to DVC-21 location in rack 22. Cables are already in position. | |||
| #61 | ITI | VARIOUS | VARIOUS | Follow up required with Pesa technician promised for on-site visit. They did not properly program the UCP-XY panels according to the spreadsheet data provided in December. | |||
| #62 | ITI | ASC02-04 | Rack 42 | Unable to verify that Cables AA0622 and AA0623 terminated in rack 7 at AAJF06 and at rack 42 in the conference room pass signal. Ostensibly originating out of ASC02 ch 2 and ASC04 channel 1 as tested though cables properly labeled and terminated at both ends. I recall that Jim Babcock was trying to get Steve Wiltsie back to complete this task as a warranty issue. | |||
| #63 | Reed/QRS | Cut and install black matte (framing shop) around TM1-4 | |||||
| #64 | Reed | Sort through utility video and audio cables and adapters to determine inventory | |||||
| #65 | Reed/Rick | Generate list of necessary additional cables and adapters | |||||
| #66 | Reed/Rick | Procure and/or fabricate additional cables and adapters | |||||
| #67 | Reed | Call Jerry Stiner at Pesa - follow up field service on Jaguar routing switcher | |||||
| #68 | ITI | Rick isolated Pesa Jaguar failure - Pesa shipping replacement module. ITI should install under warranty. | |||||
| #69 | Reed | Training required on specific equipment: Pinnacle Deko500 and Type Deko CGs, Sony VFS-700 (need manual at least!), Pesa Routing Switcher,Panasonic robotic camera, DVD-R, and DVC Pro components (optional) , Gentner (now Comrex) 612 conferencing hybrid, RTS intercom and PL system, Grass Valley Kayak production switcher | |||||
| #70 | Rick/Tom | Follow up with Juan Adrianza on repair of Tek 1750 the repair of DBETA01 (Sony DVW500) that has the intermittent error 92. It needs a replacement ribbon cable soldered in place. |
|||||
| #71 | Reed | Procure additional field equipment suggested by Rick: Delvcam Pro 56 5.6" LCD Monitor System ($200),Gentner Microtel field telco hybrid ($250), Shure FP22A headphone amp ($390), Lectronsonics UH-195D diversity wireless system w/ lav, cube and receiver ($2000) | |||||
| #72 | Rick | Training and "HOW TO" web pages required on overall system/equipment | |||||
| #73 | Jeff H | Terminate UTP (Cat 5e) cable with RJ45 crimp connectors. | |||||
| #74 | Rick | FS05 (Keywest TBC10SD) not passing signal. Bypassed and needs repair under warranty. | |||||
| #75 | Rick | CAD and Foxpro database additions for seven new Keywest TBC10 frame syncs for DVHS01-31, SatRx, and RSW41 (YC out from conference room), including Y/C in/out and reference. | |||||
| #76 | ITI | Install seven new reference cables and surplus Leitch VDA661 as needed | |||||
| #77 | Generate additional cables labels as per list sent 5/19 by Ernie B. | ||||||
| #78 | ITI-Warranty | Dress loose cables | |||||
| #79 | ITI-Warranty | Identify source of stray cables and catalog for spares (rack 1) | |||||
| #80 | ITI-Warranty | Run and terminate RJ11 cable between RJ11-JP in rack 4 to Tel21 in rack 22. | |||||
| #81 | ITI-Warranty | Install two pair RS-422 between ITI provided VTM01in rack 1 and VTM01-RM (Videotek VTM200 and RCU200) remote in rack 12U. | |||||